QC Inspection for Manholes

 

Structural Manhole

Scope:  This inspection program covers the normal fabrication operations of Manholes.

Shaft

Property

Frequency

Responsibility

Test Method

 1

 Mandrel OD

 One per machine set-up

 Q.C. Inspector

 QW 12

2.

Pipe stiffness

Once per 300 m or once per day.

Mech. Prop. Inspection

QW 03

3.

Loss on Ignition

-ditto-

Mech. Prop. Insp.

QW04

4.

Pipe wall thickness

Each pipe end 4 pts 90 deg. apart

Q.C. Inspector

Micrometer

5.

Pipe cut length

Each manhole Pipe section

Q.C. Inspector

Steel Tape

6.

Internal Barcol Hardness

Each Pipe 3 pts 120 deg. apart

Q.C. Inspector

QW 13

  Cones

Property

Frequency

Responsibility

Test Method

1

Thickness

Each Cone

Q.C. Inspector

QW 18

2.

100% visual

Each cone

Q.C. Inspector

Visual

 Assembly 

Property

Frequency

Responsibility

Test Method

1

100% visual

Each Cone

Q.C. Inspector

Visual

2.

Overall length

Each Cone

Q.C. Inspector

Steel Tape

 Final Inspection

Property

Frequency

Responsibility

Test Method

1

Marking

Each Manhole

Q.C. Inspector

Visual

2.

Visual

Each Manhole

Q.C. Inspector

Visual